InterCon Systems Info Sales and Tech Support cLGA Products Qualification Test Report Electrical Performance Mechanical Performance Product Description Home



At 1 dB loss, the product's response at varying signal-to-ground ratios is as follows:

Signal-to-Ground
Ratio
1 db Loss
Bandwidth (GHz)
3 db Loss
Bandwidth (GHz)
2:1 7.3 12.2
1:1 8.8 12.7
1:2 12.5 13.2
1:3 13.1 17.2
1:5 16.25 19.0

Inductance: less than 0.1 nH mutual
Capacitance: less than 0.02 pf mutual
Resistance: 20 milliohms nominal


A full electrical characterization test report, including bandwidth performance and equivalent circuit model characteristics, is available here.







Copyright © 2005 InterCon Systems, Inc.
Contact: Webmaster@interconsystems.com.