Contact
resistance:
|
12
milliohms initial
10 milliohm maximum change per contact after test
Full deflection/resistance curve information is
available.
|
|
Contact
force:
|
50
grams deflection force per contact
Full force/deflection curve information is
available
|
|
Mechanical
shock
(50G peak, 3 axis):
|
No
discontinuity > 2 nanoseconds
10 milliohm maximum change per contact after test
|
|
Random
vibration
(7.3 G'rms, 3 axis, 200 gm load):
|
No
discontinuity > 2 nanoseconds
10 milliohm maximum change per contact after test
|
|
Accelerated
thermal cycling
(0 to 100º C, 3500 cycles):
|
10
milliohm maximum change per contact after test
|
|
Durability
(25 cycles):
|
10
milliohm maximum change per contact after test
|
|
Dust
exposure:
|
10
milliohm maximum change per contact after test
|
|
Thermal
shock
(-55 to 85º C):
|
10
milliohm maximum change per contact after test
|
|
Cyclic
humidity (25 to 85º C):
|
10
milliohm maximum change per contact after test
|
|
Dielectric
withstanding voltage
(500 VAC):
|
No
breakdown
|
|
Insulation
resistance
(500 VDC):
|
>
50,000 megohms
|
|
Temperature
life
(90º C, 2000 hours):
|
10
milliohm maximum change per contact after test
|
|
Mixed
flowing gas
(mated, 20 days):
|
10
milliohm maximum change per contact after test
|
|
Power
cycling
(20 to 95º C, 2000 hours):
|
10
milliohm maximum change per contact after test
|
|
Current
rating:
|
1
to 3 amps per contact, depending on application. Current
rating curves for several contact configurations are available.
|