| Contact resistance: |
12 milliohms initial 10 milliohm maximum change per contact after test Full deflection/resistance curve information is available. |
| Contact force: |
50 grams deflection force per contact Full force/deflection curve information is available |
Mechanical shock (50G peak, 3 axis): |
No discontinuity > 2 nanoseconds 10 milliohm maximum change per contact after test |
Random vibration (7.3 G'rms, 3 axis, 200 gm load): |
No discontinuity > 2 nanoseconds 10 milliohm maximum change per contact after test |
Accelerated thermal cycling (0 to 100º C, 3500 cycles): |
10 milliohm maximum change per contact after test |
Durability (25 cycles): |
10 milliohm maximum change per contact after test |
| Dust exposure: |
10 milliohm maximum change per contact after test |
Thermal shock (-55 to 85º C): |
10 milliohm maximum change per contact after test |
| Cyclic humidity (25 to 85º C): |
10 milliohm maximum change per contact after test |
Dielectric withstanding voltage (500 VAC): |
No breakdown |
Insulation resistance (500 VDC): |
> 50,000 megohms |
Temperature life (90º C, 2000 hours): |
10 milliohm maximum change per contact after test |
Mixed flowing gas (mated, 20 days): |
10 milliohm maximum change per contact after test |
Power cycling (20 to 95º C, 2000 hours): |
10 milliohm maximum change per contact after test |
| Current rating: |
1 to 3 amps per contact, depending on application. Current rating curves for several contact configurations are available. |